page
2
of 2 |
|
Use RS-485 spread
spectrum serial
SCADA radio modem
or telemetry radios to link multiple Radio
Telemetry I/O Expanders - across multiple sites
- to create a modular, expandable radio
telemetry system.
|
-1: 2Ai 2Ao 2Di 2Ro |
Bidirectional Radio
Telemetry I/O
Expander, RS-485 Interface |
Interface |
2: 4-20
mA (0-22 mA) Inputs (16 bit precision) 2: 4-20 mA (0-22 mA) Outputs (16 bit
precision) 2: Discrete Inputs, Ground to assert 2: Relay outputs, dry contact |
Analog
Accuracy |
4-20
mA: .1% full-scale @ 20ºC, .2%
full-scale -40ºC to +70ºC |
Interface
Protection |
RFI
filtering all I/O, Transient suppressors
all I/O, Self-reset fuse 4-20 I/O |
DC Power |
9VDC
to 24VDC @ 150 mA (12V battery input,
solar panel input, sensor DC output)
Optional gated internal sensor power
supply 5-48 VDC @ 60 mA |
Enclosure
Size |
5" x
4" x 3" (L x W x H) |
Environmental |
-40ºC
to +70ºC; 0 to 95% humidity,
condensing |
|
-2: 8Ai |
8 4-20mA Radio Telemetry Input Expander,
RS-485 Interface |
Interface |
8: 4-20 mA (0-22 mA) Inputs (16 bit
precision) |
Analog Accuracy |
4-20
mA: .1% full-scale @ 20ºC, .2%
full-scale -40ºC to +70ºC |
Interface Protection |
RFI
filtering all I/O, Transient suppressors
all I/O, Self-reset fuse 4-20 I/O |
DC Power |
9VDC
to 24VDC @ 200 mA (12V battery input,
solar panel input, sensor DC output)
Optional gated internal sensor power
supply 5-48 VDC @ 60 mA |
Enclosure Size |
5" x
4" x 3" (L x W x H) |
Environmental |
-40ºC to +70ºC; 0 to 95% humidity,
condensing |
|
-3: 8Ao |
8 4-20mA Radio Telemetry Output Expander,
RS-485 Interface |
Interface |
8: 4-20 mA (0-22 mA) Outputs (16 bit
precision) |
Analog Accuracy |
4-20
mA: .1% full-scale @ 20ºC, .2%
full-scale -40ºC to +70ºC |
Interface Protection |
RFI
filtering all I/O, Transient suppressors
all I/O, Self-reset fuse 4-20 I/O |
DC Power |
9VDC
to 24VDC @ 400 mA (12V battery input,
solar panel input, sensor DC output)
Optional gated internal sensor power
supply 5-48 VDC @ 60 mA |
Enclosure Size |
5" x
4" x 3" (L x W x H) |
Environmental |
-40ºC to +70ºC; 0 to 95% humidity,
condensing |
|
-4: 8Di |
8 Digital Radio Telemetry Input Expander,
RS-485 Interface |
Interface |
8: Digital Inputs |
Interface Protection |
RFI
filtering all I/O, Transient suppressors
all I/O, Opto isolation all inputs |
DC Power |
9VDC
to 24VDC @ 200 mA (12V battery input,
solar panel input, sensor DC output)
Optional gated internal sensor power
supply 5-48 VDC @ 60 mA |
Enclosure Size |
5" x
4" x 3" (L x W x H) |
Environmental |
-40ºC to +70ºC; 0 to 95% humidity,
condensing |
|
-5: 8Ro |
8 Relay Radio Telemetry Output Expander,
RS-485 Interface |
Interface |
8: Relay Outputs dry contact
|
Interface Protection |
RFI
filtering all I/O, Transient suppressors
all I/O |
DC Power |
9VDC
to 24VDC @ 250 mA (12V battery input,
solar panel input, sensor DC output) Optional gated internal sensor power
supply 5-48 VDC @ 60 mA |
Enclosure Size |
5" x
4" x 3" (L x W x H) |
Environmental |
-40ºC to +70ºC; 0 to 95% humidity,
condensing |
|
Specifications subject
to change without notice |
Solar Panel Voltage,
+5VDC, TX, RX, Alarm |
|
back to
page 1>
www.synetcom.com
(310) 379-2000
23879 Madison Street
Torrance, CA 90505 |
|
|
|
|